Uploaded image for project: 'Xray for Jira'
  1. Xray for Jira
  2. XRAY-1876

Test Count custom field, in some cases, will update to the wrong value

    XporterXMLWordPrintable

Details

    • Bug
    • Status: Closed
    • Major
    • Resolution: Won't Fix
    • R2.3.0
    • None
    • None
    • None
    • NOK

    Description

      In particular useĀ cases, the Test Count custom field will not update or will update to the previous value.

      This bug is very difficult to reproduce and will occur once in a while when insisting on removing one by one the Tests from a Test Set.

      See evidences in attachements.

      In this case, the user was deleting Tests from Test Set one by one. On 23 to 22 count, the system kept 23 when it should have kept 22.

      Attachments

        Issue Links

          Activity

            People

              helder.ferreira Helder Ferreira
              xcfe Xavier Fernandes
              Votes:
              1 Vote for this issue
              Watchers:
              4 Start watching this issue

              Dates

                Created:
                Updated:
                Resolved:

                Time Tracking

                  Estimated:
                  Original Estimate - 3 days Original Estimate - 3 days
                  3d
                  Remaining:
                  Remaining Estimate - 0 minutes
                  0m
                  Logged:
                  Time Spent - 3 days, 4 hours