Uploaded image for project: 'Xray for Jira'
  1. Xray for Jira
  2. XRAY-7036

When importing data from QC, if the value for Step Order starts at 0, Tests will be migrated with a missing step

    XporterXMLWordPrintable

Details

    • Bug
    • Status: Closed
    • Major
    • Resolution: Done
    • None
    • 4.2.11
    • HPQC, Import Tests
    • None
    • XRAY 2021 Sprint 5
    • OK

    Description

      When importing data from QC, if the value for Step Order starts at 0, Tests will be migrated with a missing step.

      The following message will appear on logs:

      "2021-01-08 11:17:06,705 INFO - 1 - Move operation to out of bounds index"
      

       On the QC side, we can check the Step Order for failed Tests and they should show at least the started step with Order = 0:

       

      Workaround: 

      Users reported that a SQL update on the QC side to change the Step Order will fix the issue. Please make sure you have a backup of your data if you attempt this workaround.

       

       

       

      Attachments

        Issue Links

          Activity

            People

              bims Beatriz Silva [X] (Inactive)
              drcs Douglas Souza
              Beatriz Silva [X] (Inactive)
              Votes:
              3 Vote for this issue
              Watchers:
              2 Start watching this issue

              Dates

                Created:
                Updated:
                Resolved:

                Time Tracking

                  Estimated:
                  Original Estimate - Not Specified
                  Not Specified
                  Remaining:
                  Remaining Estimate - 0 minutes
                  0m
                  Logged:
                  Time Spent - 50 minutes
                  50m